Cyberjaya Location
iCore colocation is hosted at KUL11 on the Cyberjaya I campus in Selangor.

iCore provides server colocation at KUL11 on the Cyberjaya I campus in Selangor, Malaysia. The facility combines 2N power, N+1 cooling and access to a carrier-neutral campus network.
Jalan Cyber Point 4, Cyber 8
63000 Cyberjaya, Selangor, Malaysia
Schedule access to your equipment through iCore. Submit your request at least one business day ahead and wait for confirmation before attending.
Request a Data Centre Visit
iCore colocation is hosted at KUL11 on the Cyberjaya I campus in Selangor.
Multiple carrier entry points and a local MyIX point of presence support connectivity options at CJ1.
KUL11 uses a 2N power design and N+1 direct expansion cooling.
Raised floors, hot and cold aisles, and temperature and humidity monitoring support equipment operation.
The campus has round-the-clock security, CCTV and controlled access. iCore helps coordinate visits and onsite work.
Use this table to review the building and plan your installation. Contact iCore to confirm the configuration available for your rack and equipment.
| Category | CJ1 specifications |
|---|---|
| Location | KUL11, Cyberjaya I campus. Jalan Cyber Point 4, Cyber 8, 63000 Cyberjaya, Selangor, Malaysia. |
| Power supply | CJ1 receives two Tenaga Nasional Berhad (TNB) utility feeds, one from the Serdang substation and the other from the Kapar substation. KUL11 has a 2N facility power design. |
| Backup power | CJ1 uses UPS and standby generators. Confirm rack-level power allocation, socket types and availability of separate A/B feeds before deployment. |
| Cooling | KUL11 uses direct expansion (DX) cooling with N+1 redundancy. CJ1 data halls use hot and cold aisle layouts. |
| Temperature & humidity | CJ1 monitors data hall temperature and humidity. Published specifications list a relative humidity reference range of 40–60% RH. Contact iCore for the temperature setpoint and humidity limits for the assigned hall. |
| Fire detection | CJ1 facility specifications list high-sensitivity smoke detection above and below the raised floor, plus addressable heat and smoke detectors. |
| Fire suppression | Pre-action water mist is documented for data hall and common areas. Published specifications also list portable CO₂ extinguishers and FM-200 clean-agent protection in selected areas. Confirm the suppression system for the assigned hall. |
| Carrier access | The carrier-neutral campus has multiple carrier entry points, meet-me rooms and dual network risers. |
| Internet exchange | MyIX lists a point of presence at CJ1. Peering access depends on eligibility and technical arrangements. |
| Physical security | The campus has 24/7 security patrols, CCTV, perimeter fencing, two-factor door access and controlled visitor entry. |
| Building & floor loading | CJ1 is a purpose-built data centre with an 800 mm raised floor and a published floor-to-ceiling height of 4.5 m. Published building loads are 10 kN/m² for data hall areas and 15 kN/m² for mechanical and electrical rooms. Confirm the allowable point load and delivery route before moving heavy equipment. |
| Goods lift | Rated load: 1,905 kg. Published dimensions: 1,550 mm wide × 2,600 mm deep × 2,600 mm high. Confirm the door opening and delivery route with iCore before shipping equipment. |
| Passenger lift | Rated load: 1,020 kg. Published dimensions: 900 mm wide × 1,550 mm deep × 2,100 mm high. |
| Rack options & dimensions | iCore lists 1U, 2U, 4U, quarter-rack, half-rack and full-rack plans. Documented CJ1 cabinet configurations include 42U racks, 600 mm wide, with depths of 1,000 mm, 1,100 mm or 1,200 mm depending on the cabinet. Confirm the assigned cabinet, usable rail depth and power before ordering. |
| Campus amenities | Published campus facilities include parking, meeting rooms and workspace. Ask iCore about availability for your visit. |
| Tier III certification | Uptime Institute lists a Tier III design award for KUL11 and a Tier III constructed-facility award for KUL11 Phase 1. |
| Visitor access | Submit scheduled requests at least one business day in advance and wait for iCore’s confirmation before attending. |
Uptime Institute KUL11 award record · MyIX point of presence list
Discuss connectivity and technical services with iCore. We’ll confirm scope, availability and pricing for your deployment.
Discuss internet connectivity for your colocated infrastructure, including bandwidth and routing requirements.
Ask about peering through the Malaysia Internet Exchange point of presence at CJ1. Access depends on eligibility and technical requirements.
Explore connectivity between CJ1 and another data centre for replication, disaster recovery or multi-site operations. Availability depends on the destination and route.
Request onsite help with equipment installation, cable checks or physical troubleshooting.
Discuss migration planning, deployment, server configuration or ongoing maintenance. iCore will confirm the scope before work begins.
Arrange Smart Hands assistance for equipment installation, cable checks, physical troubleshooting or planned maintenance.
Share your rack details, visitor information and planned work in advance. Submit your visit request at least one business day ahead and wait for confirmation.
Coordinate equipment delivery and installation with iCore. We can help you confirm rack fit, power, cooling and network requirements before you deploy.
Service illustrations.
Security patrols, CCTV monitoring and perimeter fencing help protect the campus around the clock.
Two-factor door access helps restrict entry to authorised personnel.
Submit your visit request in advance, wait for confirmation and bring valid identification when you arrive.
Security illustrations.
Place your own servers at CJ1 and choose from 1U, 2U, 4U, quarter-rack, half-rack and full-rack plans. Check the plan details for included power, network and IP allocation.
Compare CJ1 PlansTell us your equipment dimensions, power draw, connectivity needs and target installation date.